Telephone Cabling

Category 3 Unshielded Twisted Pair (UTP) cable - Indoor

Category 3 Unshielded Twisted Pair (UTP) cable - Indoor

Description

AVAYO unshielded 2 to 200 insulated, color coded, copper wires twisted in to pairs, cabled together and over all jacketed with PVC or with halogen free compound, designed to support for all category 3 requirements.

Applications & Standards

  • Supports all present and future category 3 applications
  • Telephony voice wiring, 10 BASE-T, 100 BASE-T4
  • Category 3 according to ANSI/TIA-568-C.2
  • Category 3 according to W


Configuration and Physical Characters

Conductor Material : Bare Copper
Size : 26 AWG
Diameter : 0.403 mm
Insulation Material : HD-PE
Thickness : Minimum at any point 0.14mm, Maximum Average 0.17mm
Diameter : 0.84 +_ 0.03mm
Colors   : Multi color coded
Twisting Lay Length (mm) : 21 Underneath
Cabling Lay Length (mm) : 130 Underneath
Jacket Material : PVC compound or LSZH Halogen free flame retardant
Thickness : Minimum at any point 0.47mm, Maximum Average 0.50mm
Colors   : Light Grey RAL 7035.
Pulling Force : 100 N Maximum.
Short Term Bend Radius : 8 X OD mm
Long Term Bend Radius : 4 X OD mm
Operating Temperature : -20°C to +60°C
Marking on Jacket : AVAYO / cable description/meter mark.
Cable Access : Bottom cable entry protected with gaskets.



Category 3 Unshielded Twisted Pair (UTP) cable - Outdoor

Category 3 Unshielded Twisted Pair (UTP) cable - Outdoor

Description

AVAYO unshielded 2 to 400 insulated, color coded, copper wires twisted in to pairs, cabled together and tape wrapped, jelly filling and over all jacketed with UV resistant jacketing, designed to support for all category 3 requirements

Applications & Standards

  • Supports all present and future category 3 applications
  • Telephony voice wiring, 10 BASE-T, 100 BASE-T4
  • Category 3 according to ANSI/TIA-568-C.2
  • Category 3 according to ISO/IEC-11801


Configuration and Physical Characters

Conductor Material : Bare Copper
Size : 26 AWG
Diameter : 0.403 mm
Insulation Material : HD-PE
Thickness : Minimum at any point 0.14mm, Maximum Average 0.17mm
Diameter : 0.84 +_ 0.03mm
Colors   : Multi color coded
Twisting Lay Length (mm) : 21 Underneath
Cabling Lay Length (mm) : 130 Underneath
Jacket Material : UV resistant PE jacketing
Filling : Petroleum Jelly
Over all Wrap   : Plastic Tape.
Colors : Black.
Pulling Force : 100 N Maximum.
Short Term Bend Radius : 8 X OD mm
Long Term Bend Radius : 4 X OD mm
Operating Temperature : -20°C to +60°C
Marking on Jacket : AVAYO / cable description/meter mark.


Top